CASMED 740 Vital Signs Monitor

CASMED 740 Vital Signs Monitor

Brand: CASMED
Type: Monitors
Web ID: 1191
Condition: Brand New

0 item is in your cart. View cart now

Need help?

Get an Equipment Quote

(781) 302-6019

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The CASMED® 740 monitor offers leading-edge technology in a rugged, portable, lightweight unit that weighs only 1.4 kg (3 lbs).

Easy to use, reliable, accurate, with multi-parameter capabilities

  • Fast, accurate blood pressure readings for neonates through adults . . . reduces the problems of motion in blood pressure measurement
  • Monitor oximetry and temperature either continuously or in a "spot-check" mode
  • Ideal for medical/surgical patients on pain medications including PCA pumps, endoscopy procedures, and for the EMS market

Featured Technologies

  • CASMED's proprietary MAXNIBP® technology

Oximetry choices include:

  • Masimo SET®
  • Nellcor® OxiMax®
  • Nonin®

Four models available:

  • CAS 740-1: MAXNIBP
  • CAS 740-2: MAXNIBP and SpO2
  • CAS 740-2T: MAXNIBP and Temperature
  • CAS 740-3: MAXNIBP, SpO2 and Temperature

Features

  • Created with emergency medical responders in mind
  • Wireless (infrared) printer option
  • User removable NiMH battery pack, internal power supply and DC power option
  • Flexible mounting solutions include cart, IV pole, bedrail, or wall; it can be fixed to a swivel wall mount designed specifically for emergency vechicles or carried in a protective, durable case

Optional Accessories

  • Infrared printer
  • RS-232 interface
  • Swiveled hard mount (for ambulance applications)
  • Roll stand and basket
  • Protective carrying case

Specifications

Physical Weight & Dimensions

  • Height: 6.75 inches (17 cm)
  • Width: 8.5 inches (21.5 cm)
  • Depth: 3 inches (7.5 cm)
  • Weight: 3 kg (1.4 lbs)

NIBP

  • Technique: Oscillometric (MAXNIBP® Technology)
  • Patient Range: Adult – Neonate
  • Measurement Range:
    • Systolic: 30-255 mmHg
    • Diastolic: 15-220 mmHg
    • MAP: 20-235 mmHg
  • Pulse Rate Range: 30-240 BPM
  • Accuracy:
    • Blood Pressure: ± 5 mmHg standard deviation no greater than 8 mmHg
    • Pulse Rate: ± 2% or ±2 BPM, whichever is greater

Oximetry (Options)

  • Masimo SET®
    • SpO2 Range: 0-100%
    • SpO2 Accuracy:
      • 70-100%, ± 2 digits (1 S.D.) Adult
      • 70-100%, ± 3 digits (1 S.D.) Neonate
    • Pulse Rate Range: 25-240 BPM
    • Pulse Rate Accuracy: ± 3 BPM
  • Nonin®
    • SpO2 Range: 0-100%
    • SpO2 Accuracy:
      • 70-100%, ± 2 digits (1 S.D.) Adult
      • 70-100%, ± 3 digits (1 S.D.) Neonate
    • Pulse Rate Range: 18-240 BPM
    • Pulse Rate Accuracy: ± 3% or ±1 digit, whichever is greater
  • Nellcor® OxiMax®
    • SpO2 Range: 1-100%
    • SpO2 Accuracy:
      • 70-100%, ± 2 digits (1 S.D.) Adult
      • 70-100%, ± 3 digits (1 S.D.) Neonate
  • Pulse Rate Range: 20-240 BPM
  • Pulse Rate Accuracy: ± 3 digits

Temperature (Optional)

  • Welch Allyn SureTemp® Plus:
    • Temperature Range: 29 °C to 42 °C (84.2 °F to 107.6 °F)
    • Accuracy: ± 0.1 °C (± 0.2 °F)
    • Meets or exceeds ASTM Standards

Control Panel

  • Display: LED display of measurement results, instructions, troubleshooting messages, and signal strength bar
  • Parameters Displayed: Systolic Pressure, Diastolic Pressure, Mean Arterial Pressure (MAP), Pulse Rate, %SpO2, Temperature (°C or °F)

Patient Alarms

Adjustable high and low alarms for Pulse Rate, SpO2, Systolic Pressure, Diastolic Pressure and Mean Arterial Pressure

Operating Modes

  • History: Review of previous measurements
  • NIBP: Manual, STAT or Automatic (at preset intervals)
  • %SpO2: Continuous Monitoring
  • Temperature: Predictive or Continuous

Power

  • Source: External line or internal battery
  • AC Power: 100-240 VAC, 50-60 Hz, 0.5A; T1.25A L250V fuse rating
  • DC Power (EMS Option): 12-30 VDC
  • Battery: NiMH battery pack (removable)
  • Charge Time: 4 hours
  • Operating Time: Minimum 4 hours of continuous operation
  • Leakage Current: 100 _A (maximum)

Safety Limits

  • 145 mmHg (Neonate)
  • If measurement time exceeds 120 seconds (Adults), 90 seconds (Neonate)
  • If safety timer detects microprocessor failure

Operating Environment

  • Operating Temperature: 0°C to 50°C (32°F to 122°F)
  • Storage Temperature: -20°C to 65°C (-4°F to 149°F)
  • Humidity: 15 - 95%, non-condensing
  • Altitude: Up to 3048 meters (10,000 feet) if stored or used outside temperature and humidity ranges.

Standards

  • ANSI/AAMI SP-10
  • EN 60601-1, EN 60601-1-2, EN 865, EN 60601-2-30, EN 60601-2-49
  • ETL Listed – UL 60601, CAN/CSA C22.2 No. 601.1
  • CE Marking according to Directive 93/42/EEC
-->