Integrated Display Screen displays easy-to-read real time graphics in waveform or bar scale format, providing the following measured and calculated numerical values to assist with ventilator management:
Allows you to blend oxygen within the unit in concentrations ranging between 21-100% without auxiliary oxygen tubing attached to the mask.
Pressure regulation at the mask allows you to regulate pressure therapy to assure delivery where it counts (not inside the machine), and automatically adjusts for variations.
Upgradeable features provide flexibility in your purchase decision, now and in the future. The Vision System gives you the ability to upgrade instead of buying a new machine for each medical revolution.
Optimum Response Automatically. The innovative development ofAuto-TrakSensitivityTM enables the BiPAP Vision System to automatically respond to changing breathing patterns and circuit leaks by identifying leaks and adjusting variable sensitivity thresholds for optimum response with every breath.
Parameters | Control Range | Control Increment |
---|---|---|
IPAP | 4 to 40 cm H2O | 1 cm H2O |
EPAP | 4 to 20 cm H2O | 1 cm H2O |
CPAP | 4 to 20 cm H2O | 1 cm H2O |
Rate | 4 to 40 BPM | 1 BPM |
Timed Inspiration | 0.5 to 3.0 sec | 0.1 sec |
IPAP >Rise Time | 0.05 to 0.40 sec | 4 set points: .05, .1, .2, .4 sec |
Oxygen Concentration (%O2)* | 21 to 100% | 4% from 21 to 25% 5% from 25 to 100% |
*With optional Oxygen Module
Alarm | Control Range | Control Increment |
---|---|---|
High Pressure | 5 to 50 cm H2O | 1 cm H2O |
Low Pressure | Disabled;0 to 40 cm H2O | 1 cm H2O |
Low Pressure | Delay 0 to 60 sec | 1 sec |
Apnea | Disabled; 20 to 40 sec | 4 set points: Disabled, 20, 30, 40 sec |
Low Minute Ventilation | Disabled; 1 to 99 L/min | 1 L/min |
High Rate | 4 to 120 BPM | 1 BPM |
Low Rate | 4 to 120 BPM | 1 BPM |
Parameters | Control Range | Control Increment |
---|---|---|
IPAP | 0 to 50 cm H2O | 1 cm H2O |
EPAP | 0 to 50 cm H2O | 1 cm H2O |
CPAP | 0 to 50 cm H2O | 1 cm H2O |
Rate | 0 to 150 BPM | 1 BPM |
Exhaled Tidal Volume (VT) | 0 to 4000 ml | 1 ml |
Minute Ventilation (Min Vent) | 0 to 99 L/min | 1 L/min |
Total Leak (Tot Leak) | 0 to 300 L/min | 1 L/min |
Patient Leak(Pt. Leak) | 0 to 300 L/min | 1 L/min |
Peak Inspiratory Pressure (PIP) | 0 to 50 cm H2O | 1 cm H2O |
Percent of Patient Triggered Breaths (Pt. Trig) | 0 to 100% | 1% |
Ti/Ttot | 0 to 100% | 1% |